Thread
DiscussionPlumbing

CO meter went off before I hit the bottom of the basement stairs

Asked by Gio O. · Sep 7

service call in a 4-family in union city, water heater "making a smell." basement door was shut. my CO meter started going off before i got to the bottom of the stairs. flue pipe had come apart at the chimney. got out, got the tenants out of the first floor, called the gas company from the sidewalk. they shut it down. the super was mad at ME lol. 4 years in and never had my meter go off like that. how many of you actually carry one, and actually turn it on?

14 replies

MB
Marcus B.
Foreman, Inside Wireman (IBEW) · 19 years · Morris County, NJ
Mentor✓ Accepted answer

Glad you're okay. What you did is the right order: get out, get others out, call the utility or 911 from outside, and don't go back in until it's been cleared. A personal CO meter is PPE, same as your glasses. Bump test or check it the way the manufacturer says, so you know it works when you need it. Different trade, same rule. Stay safe.

36 helpful · Sep 8
Kash_sing
HVAC contractor, owner · 25 years · Middlesex County, NJ
Mentor

What every one of my techs carries on every call: - Personal CO meter, on, before entering the basement - Combustion analyzer on any fuel-burning work - The gas utility's emergency number saved in the phone And they're trained to leave first and diagnose second.

12 helpful · Sep 16
RT
Rui Teixeira
Master Plumber, second-generation shop owner · 23 years · Hudson County, NJ
Mentor

Scary one. My father had a call like that in Harrison years ago. What I'd tell a young guy: if the meter goes off, open it up, let it air out, and once the meter clears, fix the flue and get on with it.

9 helpful · Sep 9
MS
ms_almonte
Vo-tech instructor, plumbing & HVAC · 28 years · Passaic County, NJ
Mentor

On the bump testing Marcus mentioned: first, follow the manufacturer's calibration and bump-test schedule. It's in the manual and it's not optional. Second, a cheap meter that works beats an expensive one sitting in the truck. Third, if nobody knows when yours was last checked, assume it hasn't been. Ask me how I know.

7 helpful · Sep 8
RT
Rui Teixeira
Master Plumber, second-generation shop owner · 23 years · Hudson County, NJ
Mentor

You're right, Ziggy. I said that wrong. Out first, utility or fire department, then the work. Thanks for catching it.

5 helpful · Sep 9
codebook_dale
Electrical inspector (former contractor) · 26 years · Ocean County, NJ
Mentor

Not legal advice, just how I'd look at it: once you're allowed back in, make sure the building's CO alarms are there and working. A flue that came apart at the chimney may also mean somebody did work without an inspection. Worth noting on your ticket.

5 helpful · Sep 15
MB
Marcus B.
Foreman, Inside Wireman (IBEW) · 19 years · Morris County, NJ
Mentor

Yes, buy your own. You won't always be standing next to your lead. And for the electricians reading: we spend plenty of time in rooms with fuel-burning equipment too, and the meter doesn't care what trade you're in.

4 helpful · Sep 21
JO
joe.plumb
New plumber · 2 years · Camden County, NJ

we got ours from the shop this summer... nobody told us anything about bump testing. going to ask monday

2 helpful · Sep 8
oldsteam_zig
Master Plumber · 28 years · Bergen County, NJ
Mentor

Respectfully, Rui, I wouldn't tell a young guy that. Get out first. Let the gas company or the fire department clear the building and find the source. Then you come back. Airing it out and going back to work is how good mechanics end up in the hospital.

2 helpful · Sep 9
HE
hec_does_ac
HVAC Service Lead · 15 years · Camden County, NJ
Mentor

So this one time in AC... hotel kitchen, the exhaust fan was dead and everyone had headaches and blamed the heat lol. my meter was the only reason we figured it out. carry it everywhere

2 helpful · Sep 17
Kearny_Pipefitter
plumber helper · 1 year · Hudson County, NJ

bayonne helper here, about 7 months in. i don't have a meter, my lead does. should i buy my own or is that overkill?

2 helpful · Sep 17
Gio O.
plumber · 4 years · Hudson County, NJ

update on the super: he said i 'broke it' when i was looking at it lol. the gas company guy told him it had been off the chimney a while. he shut up after that

1 helpful · Sep 16
Gio O.
plumber · 4 years · Hudson County, NJ

appreciate everybody. went back to that building today. new flue, CO alarms in the basement now. super even said thanks. kind of

1 helpful · Sep 21
JO
joe.plumb
New plumber · 2 years · Camden County, NJ

follow up: asked about bump testing like ms almonte said. nobody at my shop knew either lol. we're doing it now

1 helpful · Sep 21
Sign in to add your reply.